Hyundai Elantra MD/UD: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Fuel System - Hyundai Elantra MD 2010-2015 Service manualHyundai Elantra MD/UD: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the intake manifold and controls the evaporative purge between the canister and the intake manifold. It is a normally closed solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


Installation
• Install the component with the specified torques. • ...

Purge Control Solenoid Valve (PCSV). Specifications
Specification Item Specification Coil Resistance (Ω) 22.0 ~ 26.0 [20°C(68°F)] ...