Install the component with the specified torques.
|
•
|
Note that internal damage may occur when the component
is dropped. In this case, use it after inspecting.
|
|
•
|
Be careful of foreign material not to flow into the valve.
|
|
1. |
Installation is reverse of removal.
Variable intake solenoid valve
bracket installtion bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
|
|
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Disconnect the variable intake solenoid valve connector ( ...
Description
Canister Close Valve (CCV) is normally open and is installed on the canister
ventilation line. It seals evaporative emission control system by shutting the