Install the component with the specified torques.
|
•
|
Note that internal damage may occur when the component
is dropped. In this case, use it after inspecting.
|
|
•
|
DON’T use a cleaner, spray, or grease to sensing element
and connector of the sensor because oil component in them may
malfunction the sensor performance.
|
•
|
Sensor and its wiring may be damaged in case of contacting
with the exhaust system (Exhaust Manifold, Catalytic Converter,
and so on).
|
|
1. |
Installation is reverse of removal.
Heated oxygen sensor installation
[SULEV]:
39.2 ~ 49.1 N.m (4.0 ~ 5.0 kgf.m, 28.9 ~ 36.2 lb-ft)
Heated oxygen sensor installation
[ULEV]:
39.2 ~ 49.1 N.m (4.0 ~ 5.0 kgf.m, 28.9 ~ 36.2 lb-ft)
|
|
[SULEV]
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Disconnect the connector (A), and th ...
Description
Accelerator Position Sensor (APS) is installed on the accelerator pedal
module and detects the rotation angle of the accelerator pedal. The APS is one
of the most important senso ...